This manual introduces the installation and maintenance methods of PN6510930 SpaceSaver electric booster hot water heaters.
This manual provides installation and service instructions for the PN6 510930 electric booster hot water heater, designed for commercial dishwashers. It covers technical specifications, installation codes, piping requirements, and safety precautions. The heater delivers 180°F rinse water and must be installed in compliance with local electrical and plumbing codes. Safety warnings include risks of electric shock and explosion if flammable materials are nearby. The unit must be grounded and connected with proper piping, including a shock arrestor expansion tank and insulated lines.
| Maximum Operating Pressure | 130 p.s.i. |
|---|---|
| Maximum Operating Water Temperature | 210 ºF |
| Water Capacity (4-18kW) | 4.27 US Gallons |
| Water Capacity (24-54kW) | 5.80 US Gallons |
| Inlet and Outlet Pipe Size | 3/4” NPT |
Maximum Operating Water Temperature 210 ºF.
Water Capacity in booster – 4 - 18kW 4.27 US Gallons.
Voltage range 208 Vac to 600 Vac.