This manual provides information on the operation and maintenance of the Lantec 200, 540, and 750 electric winches
This manual provides detailed instructions for operating, installing, lubricating, and maintaining Allied Lantec 200, 540, and 750 electric winches. It includes sections on gear lubrication schedules, mounting procedures, start-up steps, and maintenance intervals. The document also covers disassembly and reassembly of components like brakes and gear reductions, along with troubleshooting for common issues such as winch failure to pull load or brake malfunction.
The manual emphasizes safety, recommending that only qualified personnel perform maintenance and warning against welding or operating the winch without reading the instructions. Lubrication guidelines are provided for different ambient temperatures and speeds, with specific oil viscosity recommendations. Storage lubrication and oil change intervals are also specified, including oil analysis recommendations for high-temperature or dusty environments.
| Gear Ratio (Model 20X) | 6.00:1 (First Reduction) / 6.00:1 (Second Reduction) |
|---|---|
| Recommended Oil Viscosity (High Speed, 100+ rpm) | AGMA 2EP ISO VG68 68 cSt at 40°C |
| Recommended Oil Viscosity (Low Speed, <100 rpm) | AGMA 3EP ISO VG100 100 cSt at 40°C |
For speeds greater than 100 rpm, use AGMA 2EP ISO VG68 68 cSt at 40°C.
The first oil change is after 300 hours of operation, then every 500 hours or annually, whichever comes first.
Possible causes include excessive load weight, an open circuit breaker, or a brake that is not releasing. Reduce wraps of wire on the drum, reset the circuit breaker, or consult the electric motor manual for brake issues.