ELT SENSOR D-300(LG) Carbon Dioxide Sensor Module User Manual

The D-300(LG) is the world's smallest dual-wavelength carbon dioxide sensor module with long life, convenient use, excellent temperature compensation, long-term stability, baud rate selection, sleep mode function and low power consumption.


ELT SENSOR D-300(LG) Carbon Dioxide Sensor Module User Manual - cover page
Brand
ELT Sensor
Document type
User Manual
Language
Chinese
Pages
9
File format
PDF
File size
952 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
FA8A298A36254F40A7599DA5719999E6

About this manual

The D-300(LG) is a compact, dual-wavelength CO2 sensor module using non-dispersive infrared (NDIR) technology. It features built-in temperature compensation, low power consumption, and configurable output modes including TTL-UART, I2C, and analog voltage. The sensor is designed for applications in homes, hospitals, greenhouses, and industrial settings. It operates within a wide temperature range (-20°C to 50°C) and offers manual and automatic calibration options for accuracy.

The module includes pins for TTL, I2C, and analog outputs, with calibration pins for 0 ppm and 400 ppm reference gases. It supports UART baud rates of 9,600, 19,200, and 38,400 bps, and can be configured for alarm output or PWM. The sensor has a 10-year lifespan under 0–95% humidity and supports extended use in high-humidity environments with specific models. This manual is written in Chinese.

What's inside

  • Sensor Specifications
  • Output Options
  • Calibration Methods
  • Pin Configuration
  • Communication Protocols
  • Alarm and PWM Output
  • Operating Environment
  • Installation and Handling Notes

Specifications

Detection MethodNDIR (Non-Dispersive Infrared)
Detection Range0~2,000 ppm (0 ~ 3,000/5,000/10,000ppm, 2%, 3%, 5% 可选)
Accuracy±75ppm (reading value)
Response TimeT90 < 150 seconds (1/e < 90 seconds)
Operating Temperature-20 ~ 50℃
Operating Humidity0 ~ 95% RH (condensation conditions), 0 ~ 99% RH (no condensation)
Dimensions33 x 33 x 13.1mm (L x W x H)
Input Voltage5V ± 5%
Average Current23mA (peak < 400mA)

Frequently asked questions

What is the detection range of the D-300(LG) sensor?

The detection range is 0~2,000 ppm, with optional ranges of 0~3,000 ppm, 0~5,000 ppm, and 0~10,000 ppm.

What output options are available for the D-300(LG)?

The sensor supports TTL-UART, I2C, alarm output, analog voltage, and PWM output.

How long is the lifespan of the D-300(LG) sensor?

The sensor has a 10-year lifespan under 0–95% humidity, and 5 years under 0–99% humidity.

What is the operating temperature range?

The sensor operates between -20°C and 50°C.