This user manual introduces Bricasti Design M21 dual mono digital to analog converter's functions and features, including installation, use and maintenance.
The M21 is a dual mono digital-to-analog converter designed for professional and consumer audio applications. It features two fully isolated channels with dedicated power supplies, DDS clocking, and analog level control to minimize crosstalk and jitter. The unit is built with precision-machined aluminum components and includes both PCM and DSD conversion capabilities. Safety and installation guidelines are provided to ensure proper operation and prevent damage from overheating or electrical hazards.
The manual covers unpacking, inspection, safety precautions, design overview, and technical specifications including power requirements, operating temperature limits, and analog output levels.
| Maximum Ambient Temperature | 40 C |
|---|---|
| Balanced Output Level | +16.5 dbm |
| Unbalanced Output Level | 8 dbm |
| Analog Converter | ADI 1955 D/A converter |
| Clocking Technology | DDS (Direct Digital Synthesis) |
The maximum ambient operating temperature is 40 C, which would yield an internal temperature of 60 C as indicated on the M21 temp display.
The balanced output level reaches +16.5 dbm, and the unbalanced output level is 8 dbm, with the front panel controlled analog attenuator set at full scale of +8 dB.
The M21 uses an ADI 1955 D/A converter in a mono configuration for PCM conversion, and an optional Ladder DAC for PCM conversion.
The M21 uses DDS (Direct Digital Synthesis) clocking for each channel, which reduces clock-induced jitter to immeasurable levels.