This manual introduces the functions and features of COMMKIT-DN, COMMKIT-PB, and COMMKIT-EN, including installation and usage methods
The document serves as an instruction manual for the Maxcess COMMKIT fieldbus interface cards, specifically the COMMKIT-DN, COMMKIT-PB, and COMMKIT-EN models. These cards enable the Cygnus controller to communicate over DeviceNet, Profibus-DP, or Ethernet/IP using an HMS AnyBus-S Slave interface. The manual details the proprietary communication protocol, including message structures, byte encoding, and parameter definitions.
| Input/Output data area size | 16 bytes |
|---|---|
| Supported Fieldbus Protocols | DeviceNet, Profibus-DP, Ethernet/IP |
| Message Identifier Size | 16-bit unsigned integer |
| Parameter Identifier Size | 16-bit unsigned integer |
| Parameter Data Types | unsigned short, integer, float |
The cards support communication over DeviceNet, Profibus-DP, and Ethernet/IP.
The Cygnus reads and writes multi-byte data in big endian format.
A value of 0x0000 indicates a read operation to read data from the Cygnus.
Parameter ID 47 is used to set the RollWidth.