Elevator testing system user manual, can test the elevator start acceleration and braking deceleration, as well as the vertical and horizontal vibration acceleration of the elevator.
This manual guides users through installing and operating the AETE Elevator Testing System, which measures elevator acceleration, deceleration, and vibration. It includes setup instructions, test procedures, data saving, and filtering options. The system connects via serial cable to a computer and features a Chinese interface with real-time data display and automatic zeroing.
The system supports 7200Hz sampling and 1200Hz effective data frequency, with built-in filters (20Hz–200Hz) and ±2% peak error tolerance. It allows saving data in *.lif format and viewing historical tests via file open functions. The software includes menus, toolbars, and status bars for intuitive control. This manual is written in Chinese.
| Sampling Frequency | 7200Hz |
|---|---|
| Effective Data Frequency | 1200Hz |
| Maximum Test Time | 83.33 seconds |
| Acceleration Peak Error | ±2% |
| Supported Filters | 20Hz, 30Hz, 50Hz, 100Hz, 200Hz, no filter |
Connect using a dedicated serial cable to the computer’s serial port.
Data is saved in *.lif format as unprocessed double-precision floating-point data.