User manual of HLN-11 series vickers hardness tester, including two models: HLN-11A and HLN-11C
This manual provides detailed instructions for operating the Dai Shi HLN-11 series Vickers hardness tester, including setup, testing procedures, and troubleshooting. It covers two models: HLN-11A and HLN-11C, with the latter supporting various impact devices. The device is designed for portable, high-precision hardness testing across multiple industries.
The manual includes sections on test principles, sample preparation, impact device specifications, calibration using standard blocks, and maintenance. It also addresses common issues and provides guidance for repair and calibration services offered by the manufacturer. This manual is written in Chinese.
| Impact Device Types | D, DC, D+15, C, G, E |
|---|---|
| Accuracy | Relative error ±0.8% (HLD=800) |
| Operating Temperature | 0~40℃ |
| Operating Voltage | 4.7V~6.0V |
| Weight | 0.675Kg (standard configuration) |
HLN-11A supports only the D-type impact device; HLN-11C supports D-type and various other impact devices.
The relative error is ±0.8% at HLD=800.
0 to 40 degrees Celsius.
Use standard Vickers hardness blocks and follow the calibration procedure outlined in section 10.