About this manual

This manual provides step-by-step instructions for installing, maintaining, and using the APsmart RSD-S-PLC and Transmitter components in a photovoltaic system. It covers safety precautions, product specifications, installation procedures, and technical parameters for each device. The system is designed to comply with NEC 2017&2020 standards and SunSpec requirements for rapid shutdown functionality.

The RSD-S-PLC is a component-level shutdown controller, while the Transmitter-PLC and its outdoor kit send shutdown signals to enable quick component disconnection during emergencies. Both devices require professional installation and must be used in accordance with local electrical codes and safety guidelines. This manual is written in Chinese.

What's inside

  • Important Safety Instructions
  • RSD-S-PLC Product Introduction
  • Transmitter Product Introduction
  • Rapid Shutdown System Overview
  • RSD-S-PLC Installation
  • Transmitter Installation
  • Technical Parameters - RSD-S-PLC
  • Technical Parameters - TRANSMITTER-PLC
  • Technical Parameters - TRANSMITTER-PLC-OUTDOOR KIT
  • Ordering Information

Specifications

Input (DC) Voltage Range8-80V
Maximum Continuous Input Current15A
Output (DC) Voltage Range8-80V
Maximum System Voltage1000V/1500V
Operating Temperature Range-40°C ~ +85°C
Dimensions (without cables)129mm x 30mm x 16mm
Input Voltage (Transmitter-PLC)12 VDC
Input Current (Transmitter-PLC)0.8A
Maximum Current (Transmitter-PLC)300A (150Ax2)
Maximum MPPT String Voltage1500VDC
Operating Temperature Range (Transmitter-PLC)-40°C~+100°C
Dimensions (Transmitter-PLC)90x35x40mm
Protection Rating (Transmitter-PLC)IP30
Dimensions (Transmitter-PLC-Outdoor Kit)198.5 mm x 298 mm x 179 mm
Protection Rating (Transmitter-PLC-Outdoor Kit)IP65

Frequently asked questions

What is the maximum system voltage supported by RSD-S-PLC?

The maximum system voltage is 1000V/1500V.

What is the operating temperature range for Transmitter-PLC?

The operating temperature range is -40°C to +100°C.

What are the dimensions of the Transmitter-PLC-Outdoor Kit?

The dimensions are 198.5 mm x 298 mm x 179 mm.

What is the protection rating of the Transmitter-PLC-Outdoor Kit?

The protection rating is IP65.