This is a technical manual that introduces the technical details of the United Scaffold System
This technical manual provides detailed test procedures and allowable load specifications for the Ring-Loc System scaffold components. It includes testing for ledgers, double ledgers, cross braces, and anchor points, all compliant with Canadian and U.S. safety standards. The document also covers personal protection equipment (PPE) tie-off requirements and test results for safety validation.
| Standard Spacing | 102 mm (4") |
|---|---|
| Maximum Load for 45° Cross Brace | 7700 lb/ft |
| Safe Working Load for Horizontal Shear | 2943 lbs |
Testing is conducted in accordance with CAN/CSA – S269.2 – M87, ANSI/ASSE A10.8-2001, and other relevant ASTM standards.
The maximum load for a 45° cross brace at rosette is 7700 lb/ft.
The safe working load for horizontal shear testing is 2943 lbs.