This manual introduces the use of EE-IR-RCVR-SM, EE-IR-RCVR-TT and EE-IR-RCVR-TUBE products, including package contents, installation, connection and use methods.
This manual provides step-by-step instructions for installing Episode® IR receivers, including placement, mounting, wiring, and cable extension. It covers three models: EE-IR-RCVR-SM, EE-IR-RCVR-TT, and EE-IR-RCVR-TUBE, with specific details for each. The guide includes wiring diagrams, adapter usage, and notes on cable length and polarity. It also includes product specifications and warranty information.
| Power | +12VDC @ 25mA |
|---|---|
| Recommended Cable Length | 1000' with CAT 5 cables |
| Carrier Frequency Acceptable Range | 30kHz to 60kHz |
| Control Range | 4' to 40' without speaker grille, 2' to 28' with speaker grille |
| Control Angle | 0+/- 45° off axis |
| Dimensions (EE-IR-RCVR-TABLE) | 0.86" H x 3" W x 1.42" D |
Drill a 1/2" hole, pass the lead and body through, and secure from the rear with the supplied nut.
1x 3.5mm to 3-pin Male Screw Terminal Adapter, 1x 3.5mm to 3-pin Female Screw Terminal Adapter, and 2x Adhesive Strips (for SM/TT models).
Yes, remove the screw, open the plastic housing, remove the module and adhesive strips, and use as a surface-mount IR Receiver.
3-Year Limited Warranty covering parts and labor for defects in material or workmanship under normal use.