This is a user manual for the O.P.L.™ One Person Loader Spreader/Feeder
This manual provides detailed instructions for installing, operating, and maintaining the O.P.L.™ One Person Loader Spreader/Feeder. It includes safety guidelines, step-by-step procedures for setup and daily use, preventive maintenance schedules, operating principles, and troubleshooting tips. Sections cover mechanical and electrical systems, compressed air requirements, and repair procedures for components like belts, clamps, sensors, and air cylinders.
The manual also includes technical specifications for different models, such as motor power ratings, voltage and frequency compatibility, compressed air pressure requirements, and shipping weights. It is intended for operators and maintenance personnel to ensure safe and efficient operation of the equipment.
| Output Speed | Variable Speed Drive |
|---|---|
| Motors | Total 11/2 (1.1) HP (kW), Lower Spreader left 1/3 (0.25) HP (kW), Lower Spreader right 1/3 (0.25) HP (kW), Upper Spreader 1/2 (0.37) HP (kW), Exit Conveyor 1/3 (0.25) HP (kW) |
| Compressed Air Maximum Use | 8 CFM (227 l/min) |
| Operating Pressure | 85-120 PSI (580-820 kPa) |
| Upper Spreader Clamps PSI | 60 PSI (410 kPa) |
| Approximate Shipping Weight (Domestic) | 1600 lb (725 kg) |
| Approximate Shipping Weight (Export) | 2100 lb (952 kg) |
Operating pressure is 85-120 PSI (580-820 kPa).
Maximum compressed air use is 8 CFM (227 l/min).
Factory recommended setting is 60 PSI (410 kPa); adjust as necessary with caution when testing.