This manual describes the use and maintenance of the SUTO S435 vortex flow meter.
This manual provides detailed instructions for operating the SUTO S435 vortex flow meter, designed for saturated steam applications. It covers safety precautions, installation requirements, electrical connections, and parameter settings. The device uses the Karman Vortices principle and features IP65 protection, 24VDC power supply, and Modbus communication. Users must follow safety guidelines to avoid injury or damage. The manual includes technical specifications, dimensional drawings, and troubleshooting guidance for proper installation and operation.
The S435 is a wafer-type flow meter with DN40 to DN300 nominal diameters, made of 304 stainless steel, and supports temperature ranges from -40°C to +250°C. It offers ±1.5% accuracy and includes pulse and Modbus outputs. Installation must ensure correct flow direction, proper flange alignment, and protection from mechanical stress or direct sunlight.
| Measured fluid | Steam |
|---|---|
| Nominal diameter | DN40 … DN300 wafer type |
| Temperature range | -40 … +250°C |
| Accuracy | ±1.5% of reading |
| Power supply | 24 VDC |
| Protection level | IP65 |
| Signal output | Pulse output / Modbus |
| Wetted parts material | 304 stainless steel |
| Range ratio | 10:1 |
Do not exceed the maximum operation temperature at the sensors tip.
The power supply is 24 VDC.
The accuracy is ±1.5% of reading.