This document is the EZFill Foam Tank Refill System Installer/User Guide, which mainly introduces the use of the system and precautions.
The Class1 EZFill Foam Tank Refill System is an electronically controlled, fixed-mount unit designed for 12 or 24 volt applications. It features a 5 GPM (19 LPM) capacity and utilizes Smart-Switch technology for automatic foam concentrate refilling. The system is self-priming and shuts off automatically after 60 seconds or when the reservoir is full, supporting both single and dual-tank configurations for Class A and B foams.
| Voltage supply | +9...32VDC |
|---|---|
| Temperature range | -40°...+85°C |
| Maximum continuous current | 6A |
| Foam fill pump control output | 500mA |
| Environmental sealing | IP67 |
The system has a flow rate of 5 GPM (19 LPM).
The pump runs for sixty (60) seconds or until the tank level FULL sensor is activated.
The system is designed for 12 or 24 volt applications.