ProPAC-3 Chemical Additive Injector Field Manual, introduces how to program, normal operation, alarm operation and field calibration
This manual provides detailed instructions for operating and programming the Titan ProPAC-3 chemical additive injector, designed for petroleum product terminals. It covers batch controller programming, normal operations, alarm management, field calibration, and installation. The device uses a microprocessor to maintain additive/product ratios with up to 0.5% accuracy and communicates via RS-485. It supports both AC and DC product pulse signals and includes features like auto-calibration and field-replaceable components.
| Operating Temperature | –40 °F to +132 °F |
|---|---|
| Operating Pressure | Maximum 250 psig, maximum differential 145 psig |
| Injection Volume per Cycle | 5 cc to 685 cc |
| Flow Meter Accuracy | Up to 0.05% of rate |
| Power Requirement | 120 VAC 60 Hz or 230 VAC 50 Hz |
| Product Pulse Signal Compatibility | AC and DC |
120 VAC 60 Hz or 230 VAC 50 Hz.
Both AC and DC signals.
Yes, there are 12 alarms — 3 non-programmable and 9 programmable — for monitoring and maintaining injection accuracy.