Garvey Elevators Groundwater Treatment and Soil Vapor Extraction System O&M Manual

Includes specifications for ground water pumps, strip units, SVE and carbon tetrachloride air treatment units


Garvey Elevators Groundwater Treatment and Soil Vapor Extraction System O&M Manual - cover page
Brand
Garvey
Category
Other
Document type
Service Manual
Language
English
Pages
43
File format
PDF
File size
3.5 MB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
9C6E37E54B8EEA2197FEFD77EA734F1E

About this manual

This Operation and Maintenance (O&M) manual covers the Garvey Elevators Interim Corrective Measure (ICM) system located at a grain elevator facility in Hastings, Nebraska. The system includes groundwater extraction and treatment to prevent volatile organic compounds (VOCs) from migrating off-site, as well as a soil vapor extraction (SVE) system to remove VOCs from the soil. The document details system components, construction details, permit requirements, and provides a routine maintenance schedule for major equipment.

What's inside

  • Introduction
  • Equipment
  • Groundwater Extraction
  • Groundwater Treatment
  • System Control
  • System Operation
  • Soil Vapor Extraction System Overview
  • Permit Requirements
  • Maintenance Schedule
  • Appendices

Specifications

Power ServiceThree phase, 480 volt, 300 amp
Pump Voltage460 volt, three-phase
Shallow Well Pump Capacity40 gallons per minute at 245 feet of head
Medial Well Pump Capacity100 GPM at 260 feet of head
Air Stripper ModelCarbonair® Model OS-500
Catalytic Oxidizer ModelGlobal Technologies* Model CC10-370

Frequently asked questions

What is the purpose of the groundwater treatment system?

The groundwater treatment system pumps and treats groundwater impacted with volatile organic compounds (VOCs) and is intended to prevent impacted groundwater from migrating off the site.

What is the purpose of the soil vapor extraction system?

The soil vapor extraction system is designed to remove VOCs from the soil under the site that have yet to migrate down to the upper unconfined groundwater aquifer.

How are pump speeds controlled?

Pump speeds are controlled by Variable Frequency Drives (VFDs) located in the control panel, which regulate the pumping rate based on groundwater elevation.