Includes specifications for ground water pumps, strip units, SVE and carbon tetrachloride air treatment units
This Operation and Maintenance (O&M) manual covers the Garvey Elevators Interim Corrective Measure (ICM) system located at a grain elevator facility in Hastings, Nebraska. The system includes groundwater extraction and treatment to prevent volatile organic compounds (VOCs) from migrating off-site, as well as a soil vapor extraction (SVE) system to remove VOCs from the soil. The document details system components, construction details, permit requirements, and provides a routine maintenance schedule for major equipment.
| Power Service | Three phase, 480 volt, 300 amp |
|---|---|
| Pump Voltage | 460 volt, three-phase |
| Shallow Well Pump Capacity | 40 gallons per minute at 245 feet of head |
| Medial Well Pump Capacity | 100 GPM at 260 feet of head |
| Air Stripper Model | Carbonair® Model OS-500 |
| Catalytic Oxidizer Model | Global Technologies* Model CC10-370 |
The groundwater treatment system pumps and treats groundwater impacted with volatile organic compounds (VOCs) and is intended to prevent impacted groundwater from migrating off the site.
The soil vapor extraction system is designed to remove VOCs from the soil under the site that have yet to migrate down to the upper unconfined groundwater aquifer.
Pump speeds are controlled by Variable Frequency Drives (VFDs) located in the control panel, which regulate the pumping rate based on groundwater elevation.