Mega Swivel COM3410K and STM5810K Anchor Connectors Operation and Instruction Manual

The COM3410K and STM5810K are anchorage connectors designed to function as an interface between the anchorage and a fall protection, work positioning, rope access, or rescue system for industrial and commercial applications.


Mega Swivel COM3410K and STM5810K Anchor Connectors Operation and Instruction Manual - cover page
Brand
Mega Swivel
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
672 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
529E5B83E548BC12D488AD7C3D5E370F

About this manual

This manual provides detailed instructions for installing and operating the Mega Swivel COM3410K and STM5810K anchor connectors, designed for fall protection systems. It includes safety warnings, mounting procedures for steel and concrete, torque specifications, and compatibility guidelines. Users must be trained and follow all safety protocols to prevent injury or death.

The connectors are rated for a tensile strength of 10,000-lbf (44kN) and a working load of 2,000-lbs (907kg). Installation must be performed by a qualified person, and the anchorage must support a static load of at least 10,000-lbf. After a fall, the connector must be removed from service and destroyed.

What's inside

  • Safety Warnings
  • Use Instructions
  • Mounting Procedures
  • Loading Conditions
  • Compatibility Limitations
  • Torque Specifications
  • Materials and Compliance
  • Rescue and Fall Arrest Requirements

Specifications

Tensile Strength (UTS)10,000-lbf (44kN)
Working Load2,000-lbs (907kg)
Weight1.2-lbs (544.3g)
MaterialsZinc Plated Steel
Operating Temperature Range-40ºF to +130ºF (-40°C to +54°C)

Frequently asked questions

What is the maximum dynamic force allowed during a fall arrest?

The maximum dynamic force must be limited to 8 kN (1800-lbf). In the EU, this must be limited to 6 kN (1350-lbf).

What is the minimum concrete thickness required for installation?

The concrete must be at least 7” (178mm) thick.

What torque range is required for steel mounting?

The torque range is 75 to 90 ft-lbs (100-120Nm).

What is the regulatory compliance of this product?

Meets or exceeds ANSI Z359.18 Type A, ANSI Z359.7-2011, and OSHA 1926.502.