This document is a user manual for the Simatek GFC 16 control unit. It mainly introduces the main features, installation guidelines, electrical connections, settings, remote control, shutdown cleaning and other content of the product.
This manual provides step-by-step instructions for installing, wiring, and configuring the Simatek GFC 16 control unit, designed for managing diaphragm valves in pulse jet dust collectors. It includes safety precautions, voltage and frequency selection, parameter settings for pulse and pause times, and troubleshooting guidance. The unit supports 2–16 valves and features IP65-rated enclosure with manual or remote operation options.
The manual also details electrical connections, fuse specifications, and shutdown cleaning cycles, with diagrams for different valve configurations. It emphasizes proper installation by trained personnel and includes warnings about electrical safety, grounding, and isolation requirements.
| Enclosure | Grey ABS – transparent cover (option: 2 screws for transparent cover) |
|---|---|
| Grade of protection | IP65 |
| Dimensions | 213 x 185 x 113 mm |
| Weight | approx. 2 kg |
| Connections | Push in terminal blocks – with max. wire section of 2.5 mm² |
| Operating temperature | -10°C to +50°C (30% duty cycle) |
| Voltage input | 230 V (±10%) – 50/60 Hz / 115 V (±10%) – 50/60 Hz |
| Output voltage | 115/230/24V AC, 24 V DC |
| Power consumption | Without output: 2.5 VA; Output: 25 VA / AC or 20 W / DC |
| Pulse time | 0.01 – 9.99 sec |
| Pause time | 1 – 999 sec |
| Max duty cycle | 30% |
| Shut down cleaning cycles | 1 – 99 cycles |
| Fuse rating | 500 mA delayed 115 V / 230 V, 2 A delayed 24 V / 48 V |
The GFC 16 can control 2 to 16 valves, depending on the model configuration.
The operating temperature range is -10°C to +50°C with a 30% duty cycle.
Input options are 230 V (±10%) or 115 V (±10%) at 50/60 Hz. Output options include 115/230/24V AC and 24 V DC.