Shengmi Technology 4ECM-SMART Electrochemical Gas Sensor Module User Manual

The 4ECM-SMART module uses an electrochemical principle to detect CO, H2S, NO2, etc. Harmful gas concentration has good stability and selectivity. The module is connected with the receiving terminal by a four-wire connection method, and the gas concentration signal is output through the UART bus, which is convenient for users to use.


Shengmi Technology 4ECM-SMART Electrochemical Gas Sensor Module User Manual - cover page
Brand
盛密科技
Document type
User Manual
Language
Chinese
Pages
8
File format
PDF
File size
345 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
94B962982872B5B3566A074DA7B97A12

About this manual

This is the user manual for the 4ECM-SMART electrochemical gas sensor module by Shengmi Technology. It detects toxic gases like CO, H2S, and NO2 using a three-electrode sensor. The module communicates via UART with a four-wire connection and supports Modbus commands for reading data, zeroing, calibrating, and changing settings. It operates on 3.5–5.5V DC and has a working temperature range of -20°C to +50°C.

The manual includes detailed command protocols for data retrieval, calibration, zeroing, address modification, and standard gas concentration adjustment, along with CRC16 calculation methods for data integrity. Safety notes warn against use in explosive environments and advise stable power supply and ESD protection. This manual is written in Chinese.

What's inside

  • Product Description
  • Technical Specifications
  • Communication Commands
  • Zeroing Command
  • Calibration Command
  • Address Modification
  • Standard Gas Concentration Adjustment
  • CRC16 Algorithm
  • Safety Notes

Specifications

Detection GasesCO, H2S, NO2
Detection PrincipleElectrochemical
Operating Voltage(3.5 ~ 5.5) VDC
Operating Current≤ 2 mA @ +5.0 VDC
Output MethodUART (+3.3V TTL level)
Operating Temperature-20℃ ~ +50℃
Operating Humidity0% ~ 90%RH (no condensation)
DimensionsΦ 24.2 x 26.8 mm
Communication Baud Rate9600 bps
Measurement Error< ±5%FS

Frequently asked questions

What gases does the 4ECM-SMART module detect?

It detects CO, H2S, and NO2 using electrochemical sensing.

What is the operating voltage range?

It operates on 3.5 to 5.5 volts DC.

What is the communication protocol?

It uses UART with Modbus-style commands and 16-bit CRC16 for data integrity.