GF Signet 2610 Process Optical Dissolved Oxygen Sensor Operator's Manual

Signet 2610 Process Optical Dissolved Oxygen Sensor is a rugged, reliable sensor designed to deliver accurate dissolved oxygen (DO) data across a wide measuring range while reducing maintenance costs. It features the latest optical technology for DO measurement. The Gen II DO sensor comes with three standard outputs: • Digital (S3L) to communicate with Signet 9900, 9950 and 8900 instruments • 4 to 20 mA, factory default ranged 0.2 to 20 ppm • ModBus RS485 The Gen II system consists of the following: • Sensor body with removable nose cone • 10 m (32.8 ft) cable with stripped and tinned ends • Optical DO sensing cap • Titanium Temperature Sensor Description RDO is a registered trademark of In-Situ® Inc., Fort Collins, CO USA.


GF Signet 2610 Process Optical Dissolved Oxygen Sensor Operator's Manual - cover page
Brand
GF Signet
Category
Other Electronics
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
974 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
A612FED619E2A193E4C7CE0DE981C56F

About this manual

The GF Signet 2610 is a rugged, reliable Gen II optical dissolved oxygen sensor designed to deliver accurate data across a wide measuring range. It features three standard outputs: Digital (S 3L), 4 to 20 mA, and ModBus RS485, making it compatible with various Signet instruments and PLCs. The sensor body includes a removable nose cone, a 10-meter cable, an optical sensing cap, and a titanium temperature sensor.

The document provides detailed instructions on unpacking, sensor cap replacement (which has a 2-year life), and installation in pressurized piping systems using adapter kits. It also includes specific wiring diagrams for connections to 9900, 9950, 8900 instruments, PLCs, and chart recorders, along with safety warnings and care guidelines.

What's inside

  • Warranty Information
  • Safety Information
  • Care and Maintenance
  • Specifications
  • Dimensions
  • Serial Numbers
  • Unpacking the Sensor
  • Calibration
  • Wiring
  • Sensor Cap Replacement

Specifications

Sensor typeLuminescent dissolved oxygen sensor
Communications optionsDigital (S 3L), Modbus (RS485), 4 to 20 mA
Cable length32.8 ft/10 meters
Internal mounting thread1¼ NPT
Salinity range0 to 42 PSU
pH range2 to 10 pH
Barometric range507 to 1115 mbar
Range0.2 to 20 mg/L concentration, 0 to 200% saturation
Accuracy (DO)±0.1 mg/L, 0 to 8 mg/L, ±0.2 mg/L, 8 to 20 mg/L
Response time Cap T9030 sec
Response time Cap T9537 sec @ 25 °C
Resolution0.01 mg/L
Operating temperature0 °C to 50 °C (32 °F to 122 °F)
Warranty Sensor3 years from date of manufacture

Frequently asked questions

Is calibration required for the Signet 2610 sensor?

No, calibration is not required as the unit measures within 2% of reading for the life of the sensor cap.

How long does the sensor cap last?

The sensor cap has a 2-year life after the instrument takes its first reading.

What is the range of the Signet 2610 sensor?

The sensor measures a range of 0.2 to 20 mg/L concentration or 0 to 200% saturation.

Can the 4 to 20 mA and Modbus outputs be used simultaneously?

Yes, the S3L and Modbus connectors can be used simultaneously with the 4 to 20 mA output.