This document is about energy dissipator design guidelines.
This chapter serves as an introduction to energy dissipators, summarizing key information from FHWA's Hydraulic Engineering Circular Number 14 (HEC-14). It explains that unchecked erosion at culvert and storm-drain outfalls can lead to structural failure, necessitating outlet-protection measures ranging from natural scour holes to structural energy dissipators.
The text outlines design criteria, including the requirement for a minimum 10-year design frequency and the selection of appropriate dissipator types (internal, external, stilling basins, etc.) based on site conditions such as debris presence, velocity, and scour potential. It also covers erosion hazards, including local scour and long-term channel degradation, and recommends an integrated design approach for the culvert, dissipator, and channel protection.
A 10-yr design frequency must be used in all cases.
Internal Dissipators, Stilling Basins, Streambed Level Dissipators, Riprap Basins and Aprons, Drop Structures, and Stilling Wells.
An external dissipator is recommended when an outlet scour hole is not acceptable, moderate amount of debris is present, and the culvert outlet velocity is moderate with Froude number < 3.
The culvert exit velocity must be consistent with the maximum velocity in the natural channel for stable channels.