Provide steel composite bridge design charts, including multi-girder bridge and ladder deck bridge design
The document presents preliminary design charts for estimating flange area and web thickness for typical composite bridge cross sections. It covers two main configurations: multi-girder bridges and ladder deck bridges. The charts are derived using resistances from BS EN 1994-2 and actions from BS EN 1991-2, considering various load models (LM1 and LM3) and design classes (elastic and plastic). An accompanying Excel spreadsheet is also mentioned for direct plate girder sizing.
The manual includes detailed worked examples for both continuous multi-girder and continuous ladder deck bridges. These examples demonstrate how to determine main girder sizes for specific span configurations, such as a three-span continuous bridge with varying span lengths. The process involves calculating span-to-depth ratios, selecting appropriate charts based on girder spacing and type, and determining required flange areas and web thicknesses for both span and pier girders.
| Deck slab thickness | 250 mm average |
|---|---|
| Deck reinforcement | 20 mm high yield bars at 150 mm centres |
| Concrete grade | C40/50 |
| Steel grade | S355 |
| Minimum top flange width | 350 mm |
| Transverse stiffener spacing | lesser of 8 m centres or 1/3 span length |
Two load models, LM1 and LM3, were considered in the designs.
Yes, elastic (Class 3 & 4) and plastic (Class 1 & 2) designs are provided.