This document serves as an installation guide for the Sierra Automated Systems Rubicon Console, detailing the setup of the control room wiring, including the Rubicon Broadcast Console Control Surface, Meter Bridge, and various Accessory Control Panels. It explains the integration of the RIOLink hub, which manages audio inputs/outputs, optos, relays, and serial ports, powered by the SPR-200 Power Supply.

What's inside

  • Overview
  • RioLink
  • SPR-200 Power Supply
  • Turret and Surface Control Panels
  • Power Wiring
  • RIOLink Krone Blocks
  • Rubicon Control Connections
  • Meters
  • Clock
  • Timer

Specifications

Rubicon Console Communication ProtocolSAS-standard RS485 protocol
Rubicon Meter Bridge Configurationsone to five meters
Rubicon Meter Bridge ConnectionsAES3 digital audio connection
Clock Connection Typeshielded twisted wire pair
Timer Connection TypeCAT5 cable
RIOLink Audio Inputs Channels32 channels
RIOLink Audio Inputs Modulestwo rear-panel plug-in modules
RIOLink Audio Inputs ConnectorRJ21 (Centronics) 50-pin connector
RIOLink Audio Outputs ConnectorRJ21 50-pin connector
RIOLink Opto and Relay Count16 optos and 16 relays
RIOLink Opto and Relay Connectorseparate RJ21 50-pin connectors
RIOLink RS485 Ports Count16 RS485 SAS-protocol serial interface ports
RIOLink RS485 Connectorone RJ21 50-pin connector
RIOLink RS232 Ports CountTwo RS232 ports
RIOLink Additional RS232 Portsthree additional RS232 ports
SPR-200 Power Supply Portsfour 24VDC power ports
SPR-200 Power Supply ConnectorsFour SpeakOn™ connectors
Rubicon Console Power ConnectorsTwo SpeakOn connectors
Turret Panel Height6" high
Turret Panel Width1.6" wide

Frequently asked questions

What protocol do Rubicon modules use to communicate with the SAS 32KD system?

Rubicon modules communicate to the SAS 32KD system via SAS-standard RS485 protocol on RJ45 connectors.

How many meters are available in the Rubicon Meter Bridge configurations?

The Rubicon Meter Bridge is available in configurations from one to five meters.

What type of connector is used for the clock connection on the Rubicon Meter Bridge?

The clock connects with a shielded twisted wire pair and may be driven by SMPTE or ESE data.

How many SpeakOn connectors are provided on the rear of each SPR-200 Power Supply?

Four SpeakOn™ connectors are provided on the rear of each SPR-200.