This document introduces the use of Nyle Systems FDG Series 2, including specifications, operating methods, safety precautions, etc.
This manual provides instructions for operating the Nyle Systems FDG Series dryers, including setup, loading, startup, unloading, and control screen navigation. It details sensor functions, alarm handling, and scheduling. The dryer uses temperature and humidity sensors to monitor drying conditions, with data logging and remote monitoring capabilities via SD card and Ethernet.
Safety and maintenance procedures are included, such as ensuring proper sealing, checking for foreign material, and cooling the chamber before unloading. The controls package allows manual or scheduled operation, with screens for home, information, equipment, diagnostics, and trend data.
| Rack Capacity | FDG 600: 15+ racks, FDG 1000: 21+ racks |
|---|---|
| Temperature Range | Ambient - 220 °F |
| Heating Capacity | 400,000 X 3 (1,200,000 total) BTU/hr |
| Equipment Model | Heatco HPA400CS44B10MR1NR5SCQ (1), Heatco HPA400CS44B10TN1NR5SCQ (2), Comefri ANPA32 (1), Baldor CAT. NO. 1202152091-000010 (1), ABB ACS550-U1-038A-4 (1), Johnson Controls M9203-GGA-RK (2), Ruskin 30x30 CD40 (2), Grainger Part No. 4YUZ7 (2) |
Conduct a pre-load check: ensure the chamber is free of foreign material, air intake is clear, blower exhaust is clear, gas supply is on, and sensors are reading ambient conditions.
Insert an SD card into the control screen, start a cycle, and data will be logged at 1 measurement per minute to a folder named 'NyleDataLogs'.
Connect the dryer to Ethernet, install a VNC client, and enter IP address 192.168.1.61 and password 100 to access the HMI screen remotely.