This document is the integration guide of Ross Controls M35 Series Safety Exhaust Double Valves, mainly introducing the characteristics and working principle of this series of products, external images, connection methods, operation and monitoring requirements, etc.
This document serves as an integration guide for the ROSS Controls M35 Series Safety Exhaust Double Valves. It details the use of solid-state pressure sensors to provide feedback to safety control systems for external monitoring. The guide includes information on pulse testing, exhaust times, faulted flow rates, and general operation involving patented cross-flow technology and optional soft-start modules.
| Operating Pressure Range | 15 psig (1 bar) to 145 psig (10 bar) |
|---|---|
| Pulse Testing Frequency | 400ms to 600ms |
| Pulse Testing Duration | 0.4ms to 0.8ms |
It indicates that the sensors are in different states, causing the unit to fail to a mechanical safe state.
No, pulse testing of the feedback sensors is not required, though pulse testing of solenoids is encouraged.
A green Sensor Power LED indicates that power is applied to the feedback sensors.