This user manual provides step-by-step instructions for installing, operating, and maintaining the ASIN Aqua water treatment system. It includes safety warnings, setup procedures, parameter settings, and maintenance schedules for components like probes and pumps. The system controls free chlorine or redox levels and pH in pools using advanced probes and dosing mechanisms.
The manual also covers safety precautions, including handling chemicals safely, avoiding mixing pH and chlorine agents, and ensuring proper installation to prevent hazards. It includes maintenance guidelines for valves, tubes, and probes, with recommended replacement intervals based on usage and water hardness.
| Power supply | 230 V / 50 Hz |
|---|---|
| Power consumption | 14 VA |
| Fuse | T80 mA |
| Ingress protection | IP50 |
| Operating temperature and humidity | +5 to +40°C / 60% |
| Weight | 2,2 kg |
| Emplacement | wall-mounted |
| Measured and regulated value | Free chlorine or Redox, pH |
| Pump power | 60 ml/min. / max 1 bar |
| Measuring water pressure | max 1,5 bar |
Do not start disinfection until the pH value is stable in the ideal range of 7.0 to 7.4 to avoid heavy overdosing of chlorine or bromine.