This file is the installation and user manual of Octave® ultrasonic water meter.
This guide provides step-by-step instructions for installing and operating the Octave® Ultrasonic Water Meter. It includes details on handling, positioning, flange installation, grounding, and hardware versions. The meter uses ultrasonic transit-time technology to measure bidirectional water flow and is powered by two 'D' size lithium batteries. It supports multiple output modules including open collector, solid state relay, dry contact, and analog outputs. Proper installation requires specific pipe configurations and air vent placement to ensure accurate measurements.
| Maximum Working Pressure | 230 psi |
|---|---|
| Liquid Temperature | 32° to 122° F |
| Precision Class | ISO 4064 rev.2005, Accuracy Class 2 |
| Power Source | 2 ‘D’ size Lithium Batteries (not serviceable by user), up to 15 years |
| Environmental Protection | IP-68, Ambient operation temperature for display: -13° to 131° F (-25° to 55° C) |
| Display Units | Multi-line, programmable 9 digit LCD display |
| Volume Display Options | 1. Net (Forward less Reverse), 2. Forward Only, 3. Forward and Reverse Alternating 4. Reverse Only* |
| Connections | Flanges ANSI ISO for AWWA connection standard |
| Severity Levels | Environmental class C, mechanical class M1, Electromagnetic environment class E1 |
| Pressure Loss | ∆P 0.16 bar or 2.32 psi |
Octave water meters are warranted to be free from original defects in materials and workmanship for a period up to five (5) years.
The meter is powered by two 'D' size lithium batteries, which last up to 15 years.