This file is a Helm Instrument Company, Inc. product instruction manual, which introduces the function and use of this automatic die monitoring system
The Helm Instrument High Resolution Automatic Die Monitoring System detects the Bottom Dead Center (BDC) of a press using a proximity sensor. It sends a fault signal if the difference in BDC position between strokes exceeds a set monitoring range, ensuring press safety and consistency. The device can detect deviations in micrometers and is designed to operate steadily without being affected by temperature variations.
| Power supply | 100-240 VAC, 50 or 60Hz |
|---|---|
| Power consumption | Less than 15W |
| Output contact capacity | Less than 250 VAC, less than 5A |
| Number of channels | 2 and 4 |
| Detection range | 0.8 mm to 1.8 mm |
| Repeating accuracy | 1 µm (0.1µm at high sensitivity) |
| Monitoring range | Average ± 100 µm |
| Sensor type | Proximity sensor for slug detection |
| Display | LCD. blue mode with back light (320 x 240 pixels) |
| Maximum speed | 2,400 SPM |
| Operating temperature range | -10 to +50°C |
The settable range is 0 to 99 µm.
Press the Set Up key for Channel 1 within 5 seconds after power-up.
Set and fix the clearance to approximately 1.1mm.
It indicates improper adjustment of the clearance between the sensor and the approaching object.