Medium Voltage Solid State Soft Starters 2.3 - 7.2 kV Installation & Operation Manual

Introduces the characteristics and applications of Medium Voltage Solid State Soft Starters 2.3 - 7.2 kV products, including overview, specifications, design features, principles, general protection, thermal overload protection, trigger circuit, electronics circuit, etc.


Medium Voltage Solid State Soft Starters 2.3 - 7.2 kV Installation & Operation Manual - cover page
Brand
Medium Voltage Solid State Soft Starters
Document type
User Manual
Language
English
Pages
89
File format
PDF
File size
3.8 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
D4192C8ADFBAA59DD9BB74934A1E562E

About this manual

This manual provides detailed instructions for installing, operating, and programming medium voltage solid state soft starters. It covers unit specifications, control connections, startup procedures, user interface navigation, setpoint programming, metering, and maintenance. The device is an SCR-based motor controller designed for AC medium voltage motors, with programmable overload curves, phase imbalance protection, and communication options via RS-485, RS-422, or RS232.

The manual includes wiring diagrams, fault analysis, spare parts lists, and troubleshooting charts to assist with setup and maintenance. It also details programmable parameters such as acceleration/deceleration ramps, relay configurations, and RTD options for temperature monitoring.

What's inside

  • Introduction
  • Specifications
  • Design Features
  • Theory of Operation
  • General Protection
  • Thermal Overload Protection
  • Firing Circuit
  • Electronics
  • Connections
  • Start-Up

Specifications

Unit Running Overload Capacity125% - Continuous, 500% - 60 seconds
Frequency50 or 60Hz, +2Hz hardware selectable
SCR Peak Inverse Voltage Ratings6500V - 19500V (model dependent see Table 1)
Control Voltage120VAC (customer supplied)
Relays8 Relays (4 programmable): Form C contacts
BIL Rating2300V - 7200V
Overcurrent Protection Trip Level100 - 300% of motor FLA
LCD DisplayAlpha numeric LCD display
Communication ProtocolModbus RTU
Network CapacityUp to 247 devices per mode
Operating MemorySRAM loaded from EEPROM at initialization
Factory Default StorageFlash EPROM, field replaceable
Real Time ClockLithium ion battery for clock memory only

Frequently asked questions

What is the voltage range of this soft starter?

The soft starter operates in the 2.3 - 7.2 kV range.

What are the overload capacity ratings?

The unit can handle 125% continuous overload and up to 500% for 60 seconds.

What communication protocols are supported?

The device supports Modbus RTU over RS-485, RS-422, or RS232.

How many relays does the unit have?

The unit has 8 relays, with 4 programmable Form C contacts.

Download PDF (3.8 MB)