This document is the maintenance manual for MaltaDynamics Mobile Grabber, which introduces the maintenance and maintenance methods of the product, including maintenance tips, safety tips, replacement parts, anchor points, bolts, deep cycle battery care and maintenance, battery charger, battery troubleshooting, and main power switch.
This manual provides maintenance and service instructions for the MaltaDynamics XSERIES Mobile Grabber models X1240, X1250, and X1260. It outlines safety procedures, inspection schedules, and guidelines for replacing parts to ensure equipment stability and safety. The document emphasizes that maintenance should only be performed by trained personnel in a well-ventilated area.
| Torque specification for 1/4" bolts | 6ft/lbs. (8.13Nm) |
|---|---|
| Torque specification for 1/2" bolts | 57ft/lbs. (77.28Nm) |
| Torque specification for 1" bolts | 488ft/lbs. (661.64Nm) |
| Electrolyte level below fill well | 1/4" (6.35mm) |
| Maximum charging temperature | 120°F (49°C) |
Maintenance and repair should only be performed by personnel who are trained and qualified to service this aerial platform.
Water used to replenish batteries should be distilled or treated not to exceed 200 T.D.S. (Total Dissolved Solids) parts per million.