MaltaDynamics XSERIES X1240 X1250 X1260 Mobile Grabber Maintenance Manual

This document is the maintenance manual for MaltaDynamics Mobile Grabber, which introduces the maintenance and maintenance methods of the product, including maintenance tips, safety tips, replacement parts, anchor points, bolts, deep cycle battery care and maintenance, battery charger, battery troubleshooting, and main power switch.


MaltaDynamics XSERIES X1240 X1250 X1260 Mobile Grabber Maintenance Manual - cover page
Brand
Malta Dynamics
Category
Industrial Robot
Document type
Service Manual
Language
English
Pages
56
File format
PDF
File size
5.5 MB
Published
19 October, 2023
Updated
19 October, 2023
Models
X1240, X1250, X1260
MD5 checksum
CC6530F0AF0F38D568AB3831A5CEA399

About this manual

This manual provides maintenance and service instructions for the MaltaDynamics XSERIES Mobile Grabber models X1240, X1250, and X1260. It outlines safety procedures, inspection schedules, and guidelines for replacing parts to ensure equipment stability and safety. The document emphasizes that maintenance should only be performed by trained personnel in a well-ventilated area.

What's inside

  • Owners Inspection Record
  • Maintenance & Service Safety Tips
  • Replacement Parts
  • Anchor Points
  • Bolts
  • Deep Cycle Battery Care & Maintenance
  • Battery Charger
  • Hydraulics
  • Troubleshooting Guide

Specifications

Torque specification for 1/4" bolts6ft/lbs. (8.13Nm)
Torque specification for 1/2" bolts57ft/lbs. (77.28Nm)
Torque specification for 1" bolts488ft/lbs. (661.64Nm)
Electrolyte level below fill well1/4" (6.35mm)
Maximum charging temperature120°F (49°C)

Frequently asked questions

Who should perform maintenance and repair on the Mobile Grabber?

Maintenance and repair should only be performed by personnel who are trained and qualified to service this aerial platform.

What type of water should be used to replenish batteries?

Water used to replenish batteries should be distilled or treated not to exceed 200 T.D.S. (Total Dissolved Solids) parts per million.

How often should the battery charger be plugged in for equalization?

The charger should be plugged in at a minimum of monthly to ensure proper battery equalization.