Provides instructions on how to operate Powerlift magnets, including their design category, service class, and maximum working load.
This manual provides detailed instructions for safely installing, operating, and maintaining Industrial Magnetics PowerLift® lift magnets. It covers safety precautions, handling limits, magnetic pole care, and handle operation procedures. The document includes specifications for working load limits based on material thickness and surface finish, as well as guidelines for lifting angles and load balancing.
The manual emphasizes safety, including warnings against lifting people, exceeding load limits, or operating damaged magnets. It also explains how to properly position the magnet, clean surfaces, and handle the magnet’s release mechanism to avoid accidents.
| Working Load Limit (WLL) | Varies by model and material thickness |
|---|---|
| Operating Temperature Range | BasicLift™ and Creative Lift®: -76ºF (-60ºC) to 300ºF (148ºC); DynamicLift™, PowerLift®, VersaLift™: -10ºF (-23ºC) to 180ºF (82ºC) |
| Maximum Working Load Limit (WLL) - Model PNL0250 | 180 lbs (81 kg) for 1/4" material |
| De-rating Factor | 2:1 = 50% of maximum value; 3:1 = 33% of maximum value |
The WLL is the stated capacity of the magnet, calculated by applying a de-rating factor to the maximum value determined under ideal conditions.
PowerLift® operates between -10ºF (-23ºC) and 180ºF (82ºC).
Always keep magnetic poles flat and clean, never lift people, never exceed WLL, and never leave loads unattended.