This manual contains the operation and maintenance instructions for the AFL series air driven high pressure liquid pumps.
This manual provides operation and maintenance instructions for the Parker Autoclave Engineers AFL Series air-driven high pressure liquid pump. The document covers the pump's introduction, safety warnings, product specifications, and unpacking procedures. It details the installation requirements, including compressed air supply connections and liquid section setup, as well as the necessary tools for assembly.
| Operating Air Pressure | 150 psi (10 bar) |
|---|---|
| Fluid Types | oil, water and oil/water mixtures |
| Maximum Output Pressure | 15,500 PSI (1069 bar) |
| Air Inlet Connection | female 3/4" FNPT |
| Pilot Valve Connection | female 1/8" FNPT |
| Air Input Pressure Range | 15 psi to 150 psi |
No, the use of an air line lubricator is not required and is not recommended as it will purge the factory installed grease.
An air line filter with a minimum 5 microns filtration rating must be used on the supply line.
The pump should be installed in the vertical position to prevent side loading on the air piston seals.