About this manual

This guide details the safe and effective use of the MAX-A-FORM® All-Steel Concrete Forming System, including panel dimensions, bolt connections, wall ties, and self-spanning applications. It emphasizes safety compliance with industry standards and provides step-by-step instructions for installation, support, and stripping. The system is designed for high-strength, modular concrete forming with customizable panel sizes and configurations.

What's inside

  • Introduction
  • Basic Elements
  • Gang Assembly
  • Max-A-Form Self-Spanning Applications
  • Max-A-Ply® Introduction

Specifications

Panel Widths2'‑6", 3', 3'‑6", 4', 5', 6', 7', 8', 9', 10', 12'
Panel Thickness6½" for 2'‑6" through 7'‑0", 8½" for 8', 9', 10'
Maximum Concrete Pressure1500 pounds per square foot (psf)
Speed Bolts¾" x 2", A-325 equivalents

Frequently asked questions

What is the maximum concrete pressure rating for Max-A-Form?

Max-A-Form is rated at a maximum of 1500 pounds per square foot (psf) of concrete pressure.

What are the standard panel widths?

The panels are made in ten standard widths: 2'‑6", 3', 3'‑6", 4', 5', 6', 7', 8', 9', 10', 12'.

What type of bolts are used for panel connections?

¾" x 2" speed bolts, A-325 equivalents, are used one foot on center at face side gauge line.