This manual provides important information regarding the operation and service of this manifold.
The document serves as an instruction manual for REFCO 2-way manifolds, specifically the Apex M2, SM2, BM2, MK-2, Star, and Jumbo-Star models. It details the purpose of the device, which is to measure pressure in refrigeration equipment, and emphasizes that it must be used only by trained technicians for refrigeration applications involving specific refrigerants. The manual includes critical safety warnings, such as prohibitions against using the manifold with ammonia (NH3/R717) or as a pressure regulator with nitrogen.
The text covers the entire lifecycle of the manifold usage, including preparation steps like adjusting zero points and matching temperature scales to the refrigerant. It provides step-by-step instructions for connecting the manifold to a system, evacuating the system using a vacuum pump, and filling the system with refrigerant. Additionally, the manual outlines service procedures, such as checking hoses, replacing seals and gaskets, and changing valve pistons or sight glasses, along with a list of spare parts and their part numbers.
| Application | measure pressure in refrigeration equipment |
|---|---|
| Compatible Refrigerants | refrigerants indicated on the gauge |
| Pressure Limit | pressure scale indicated on the high pressure gauge |
| Valve Type | Changeable piston type valves |
| Gauge Type | Glycerine-oil filled gauges |
The manifold must be used only by trained technicians.
No, the manifold cannot be used with ammonia (NH3 / R717).
Safety goggles and gloves must be worn during the use of the manifold.