ACR RCL-100 Remote Controlled Search Light Troubleshooting and Parts Replacement Manual

This manual introduces the characteristics and usage methods of Remote Controlled Search Light, RCL-100, including fault diagnosis, repair and maintenance.


ACR RCL-100 Remote Controlled Search Light Troubleshooting and Parts Replacement Manual - cover page
Brand
ACR
Category
Other Electronics
Document type
Service Manual
Language
English
Pages
17
File format
PDF
File size
789 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
03A81FF0A025E4931887DA558353388E

About this manual

This manual provides troubleshooting tools and wiring guides for the ACR RCL-100 remote controlled search light. It details compatibility between Pointpad and Master Controller units, including specific voltage ratings for bulbs and coaxial cable extension limits.

What's inside

  • Troubleshooting tools needed
  • Wiring guide
  • Pointpad / Master controller compatibility
  • Searchlight and Wiring Diagram
  • Breakdown procedure
  • Slip ring and Planet gear assembly
  • Rotation motor assembly
  • Troubleshooting the light
  • Repair / Refurbishment of searchlights
  • Recommended maintenance

Specifications

Coaxial Cable TypeRG 59
Bulb Part Number (12V)6001
Bulb Part Number (24V)6003

Frequently asked questions

Which Master Controllers are compatible with URP 100?

URP 100 is compatible with URC 100 and URC 101.

What should be done if the light flickers on and off as it rotates?

Remove the protection cover and check the slip ring and brush assembly for corrosion; clean or replace if necessary.

Where should the light be sent for repair or refurbishment?

Send the light to Technical Service, ACR Electronics Inc. at 5757 Ravenswood road Fort Lauderdale, Fl 33312.