This manual provides running guidelines for TenarisHydril Wedge 523® / 521® connections. It is applicable for all TenarisHydril premium connections.
This document provides specific running guidelines for TenarisHydril Wedge 523® and 521® connections. It covers equipment verification, thread compound application, inspection criteria, and torque settings. Special attention is given to Dopeless® Technology connections and handling plugs. The guidelines are intended to be used in conjunction with the main TenarisHydril Running Manual and may be modified by field service representatives with client approval.
Key procedures include verifying thread compound compatibility, ensuring clean and undamaged connections, applying thread compound and thread lock correctly, and using recommended tools and speeds during assembly and disassembly.
Apply a thin coating of thread compound on the full pin end only, threads, seal and pin nose. Do not apply to the box end.
Do not exceed 15 RPM during spin in.
No, Wedge 521® and Wedge 523® connections are not interchangeable.