This manual is the user manual of 200L belt driven air compressor. It introduces the usage, maintenance and troubleshooting methods of the compressor.
This user manual provides instructions for installing, operating, and maintaining the Jefferson Tools JEFCIND200L-4.0 200L belt-driven air compressor. It includes safety guidelines, equipment identification, assembly steps, and maintenance procedures. The compressor is designed for professional workshops and features a 4HP motor, 200L tank, and compliance with European safety standards. Users must read all instructions before operation and follow safety precautions to prevent damage or injury.
The manual covers unpacking, assembly, oil level checks, environmental setup, and troubleshooting. It also includes diagrams and part lists for main assembly and pump components. Safety warnings are emphasized, including proper surface leveling, ventilation, and avoiding operation on inclines or elevated positions. The compressor requires 230V~50Hz power and must be operated with correct oil levels to ensure safe and efficient performance.
| Tank Capacity | 200L |
|---|---|
| Power | 4.0HP / 3.0kW |
| Input Voltage ~ Frequency | 230V ~ 50Hz / 16A |
| Maximum Pressure | 10bar (145psi) |
| Pump Speed | 945rpm |
| Air Displacement | 15.9 cfm (452 L/min) |
| Free Air Delivery | 9.4 cfm (266 L/min) |
| Guaranteed Sound Power | 96 dB LWA |
| Weight | NW: 146kg / GW: 182kg |
| Dimensions | 1365 x 477 x 1033mm |
The tank capacity is 200L.
The maximum pressure is 10bar (145psi).
The power rating is 4.0HP / 3.0kW.
The compressor must be used on a flat surface with a maximum safe operating angle of 10° in any direction.