This manual describes the components of the B-Van lithium battery pack, how to operate and maintain it
This manual provides operating instructions for the B-Van V5R 51.2V 210Ah Lithium Battery system. It details the components including the battery, inverter, charger, and solar setup, along with safety warnings and initial setup steps. The document explains how to turn the system on and off, manage power sources like the alternator and solar panels, and interpret system status.
| Voltage | 51.2V |
|---|---|
| Capacity | 210Ah |
| Max Discharge Voltage | 44.8V |
| Min Discharge Voltage | 50.0V |
| Max Charging Voltage | 54.8V |
| Min Charging Voltage | 54.0V |
| Standard Charging Time | 7 hours |
| Self-Heating Start Temp | 41°F (5°C) |
| Self-Heating Stop Temp | 50°F (10°C) |
| Max Discharge Temp | 140°F (60°C) |
The battery must be charged immediately to prevent under-voltage faults.
The standard charging process normally takes 7 hours.
It activates automatically when the battery temperature drops below 41°F (5°C) and a stable charge current greater than 8A is present.