Numatx NXC Series Rivet Squeezers Operation Manual

NXC Series C-Squeezers Operation Manual, including overview, specifications, safety warnings, assembly, operation, maintenance, filling and bleeding the system, contact information and parts lists.


Numatx NXC Series Rivet Squeezers Operation Manual - cover page
Brand
Numatx
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
907 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
F3CD90D0594428A333CD991E2BC769AA

About this manual

This manual provides operating instructions for the Numatx NXC Series C-Squeezers, which are hydraulically operated hand-held tools designed to squeeze a variety of rivets. These units are hydropneumatic operated and work in conjunction with Numatx pressure intensifiers, such as the NXI-40, for commercial riveting operations. The fully hydraulic design offers advantages including decreased weight, smaller size, and greater control compared to traditional pneumatic squeezers.

What's inside

  • Overview
  • Specifications
  • Safety Warnings
  • Assembly
  • Operation
  • Maintenance
  • Filing and Bleeding the System
  • Contact Information
  • Parts Lists

Specifications

Air Pressure, Min30-PSIG
Air Pressure, Max90-PSIG
Hydraulic Pressure, Normal3.500 psi
Hydraulic Pressure, Max4.500 psi
Compression Pin Travel.550" (14 mm)
Weight (NXC-4)1.25 Lbm (.56 Kg)
Weight (NXC-6)1.72 Lbm (.78 Ko)
Weight (NXC-9)2.00 Lbm (.91 Kg)

Frequently asked questions

What fluid should be used for the c-squeezer actuation?

Use Dexron II or equivalent fluid for the c-squeezer actuation fluid.

What is the minimum air pressure required for operation?

Never operate the system below 30-psig air pressure.

What is the maximum hydraulic pressure allowed?

Never operate the c-squeezers above 4.500 psi (31.0 Kq/cm2) hydraulic pressure.