Parker Hannifin F1/T1 Series Pump Service Manual

This manual introduces the new features of the F1/T1 series products, specifications, design and function, as well as how to check the shaft seal, pump flow and motor performance, and also includes disassembly, assembly, split view, spare parts and other information


Parker Hannifin F1/T1 Series Pump Service Manual - cover page
Brand
Parker Hannifin
Category
Industrial Supply
Document type
Service Manual
Language
English
Pages
14
File format
PDF
File size
1.4 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
898802C3D333725E8072ADC87C152F98

About this manual

This service manual provides technical details for the Parker Hannifin F1/T1 series piston pumps, including design features, specifications for various frame sizes, and operational limits. It details the pump's efficiency, reliability, and specific capabilities such as self-priming speeds and maximum operating pressures up to 400 bar.

What's inside

  • Specifications, design and function
  • Check of shaft seal
  • Checking the flow from the pump
  • Checking performance of the motor
  • Direction of rotation
  • Disassembling
  • Assembling
  • Spare part kits and tools
  • Conversion factors

Specifications

Max operating pressure400 bar (intermittent)
Max operating pressure350 bar (continuous)
Shaft speed2700 rpm (short circuited)
Displacement25.6 cm3/rev (Frame 25)
Weight8.5 kg (Frame 25)

Frequently asked questions

How do I check for shaft seal leakage?

Check that no oil is dripping out of the indication hole when the pump is in operation.

What is the maximum flow decrease allowed when loading?

The flow must not decrease by more than 10% when the pump is loaded up to 150-200 bar.

What is the maximum drain flow for an F01-025-M motor?

The maximum drain flow is 2.0 l/min at 150 bar pressure.