This document is the installation guide of HMS-2000-4T series microinverters. It includes component description, installation steps, and precautions.
This document serves as a quick installation guide for the Hoymiles HMS-2000-4T series microinverters. It is compatible with HMS-1600, HMS-1800, and HMS-2000 series models (including B variants). The guide details the required accessories, which must be purchased separately, and outlines the installation order for mounting the device and planning the AC bus. This manual is written in Spanish.
| Compatible models | HMS-1600/1800/2000/1600B/1800B/2000B-4T |
|---|---|
| Grounding torque | 2 Nm |
| Mounting screw torque | 9 Nm |
| AC bus plug torque | 4,0 ± 0,5 N m |
| Locking screw torque | 0,4 ± 0,1 N m |
No, all mentioned accessories must be purchased separately.
Under the photovoltaic module to avoid direct sunlight, rain, snow, and UV rays.
At least 2 cm of space is needed for ventilation and heat dissipation.