This manual is Beckett AF/AFG oil burner's user manual, which mainly introduces the burner's type, installation, adjustment and other information.
This document is the official user and service manual for Beckett AF and AFG oil burners. It covers essential safety warnings regarding fire, smoke, and asphyxiation hazards, emphasizing that installation and servicing must be performed by qualified professionals in accordance with local codes. The manual distinguishes between the AF and AFG models, noting differences in static pressure capability, blower wheel design, and air tube combinations.
| Firing rate range (F Head) | 0.40 – 3.00 GPH |
|---|---|
| Input (F Head) | 56,000 – 420,000 Btu |
| Firing rate range (L1 Head) | 0.40 - 1.10 GPH |
| Firing rate range (V1 Head) | 0.75 - 2.75 GPH |
| Electrical Power supply | 120 volts AC, 60 Hz, single phase |
| Operating load | 5.8 Amps max |
| Motor | 1/7 hp, 3450 rpm, NEMA 48M frame |
| Ignition | Continuous duty solid-state igniter |
| Maximum Height | 12.5 inches |
| Maximum Width | 15 inches |
The burner is approved for U.S. No.1 or No.2 heating oil only, and in Canada, No. 1 stove oil or No. 2 furnace oil only.
Installation, adjustment, and service must be performed by a professional, qualified service agency or licensed individual.
No, you should never try to convert an AF to an AFG or vice versa, and 'M' Series air tube combinations must not be used on AF Burners.
The maximum height is 12.5 inches, the maximum width is 15 inches, and the depth is 9.25 inches.