This document is the Power TracKer TM manual. It introduces the product's features, characteristics and usage methods.
This manual explains how to operate the Avid Power TracKer multi-mode RFID reader, including turning it on and off, scanning ID tags, and using the battery and PC interface. It details the differences between models II, IV, V, and VI in tag compatibility. The reader uses a 125 kHz/128 kHz/134.2 kHz frequency and requires Avid-approved NiMH batteries. It connects to a PC via a DB-9 serial cable and includes software support for Windows applications.
| Operating Frequency | 125 kHz / 128kHz / 134.2 kHz |
|---|---|
| Battery | AVID Nicad rechargeable batteries only |
| Battery Life | Approximately 3,000 read operations per recharge |
| Display | 16 character LCD |
| Operating Temperature | 0° to 50°C (32° to 122°F) |
| Storage Temperature | -20° to 65°C (-4° to 149°F) |
It reads AVID, Fecava, Trovan, and ISO FDX/b coded tags depending on the model.
Use a DB-9 cable with 9600 baud, no parity, 8 data bits, 1 stop bit, and no handshake.