This document is the ORS RCM 1000 Remediation Control Module Installation and Operation Manual
The ORS RCM 1000 is a microprocessor-based controller designed for use with Geotech's standard remediation equipment. It is housed in a NEMA 4 (IP 66) enclosure and accepts five intrinsically safe inputs to control one mechanical relay output and an auxiliary solid state alarm signal output. The controller requires no switches to set or programming, allowing for user-friendly installation.
| Motor Output Capacity | 1HP @ 120VAC, 2.5 HP @ 240VAC |
|---|---|
| Alarm Output Capacity | 10 Amp Max |
| Enclosure Rating | NEMA 4, IP 66 |
| Material | Fiberglass reinforced plastic |
No, there are no switches to set or programming necessary for the ORS RCM 1000.
The controller is housed in a NEMA 4 (IP 66) enclosure.
The motor supply output is capable of 1HP @ 120VAC or 2.5 HP @ 240VAC single phase.