This Installation Manual applies to both the Purotwist 3000 and 4000 models
This guide provides detailed instructions for installing the Purotwist 3000 and 4000 reverse osmosis systems. It covers drilling faucet holes, tapping into cold water lines, mounting tanks, installing filters and membranes, connecting tubing, and activating the system. Maintenance tips, such as filter replacement every six months, are also included to ensure optimal performance and longevity.
The guide emphasizes compliance with local plumbing codes and safety precautions, including avoiding hot water lines and ensuring microbiologically safe water sources. It includes specific tools and materials required for installation, such as variable speed drills, Teflon tape, and specific filter part numbers.
| Maximum Supply TDS | 2000 mg/L |
|---|---|
| System Pressure Min/Max | 30 / 100 psi |
| Temperature Range | 4° to 38°C (40° to 100° F) |
| pH Range | 3.0 to 11.0 |
| Recovery Rate | 21% |
| Efficiency Rate | 12.1% |
A 3/8” variable speed drill and a spring-loaded Relton style drill set are recommended to prevent chipping.
Filters should be changed every six months depending on the quality of the feed water supply.
The recovery rate is 21%, meaning 21% of the influent water is available to the user as treated water.
The efficiency rate is 12.1%, meaning 12.1% of the influent water is available to the user as treated water under typical daily usage conditions.