This manual provides instructions for installing and wiring GrowerSelect 3-Phase 50 Hz Feed System Auger Power Drive Units. The instructions cover general installation notes, motor installation, transformer installation, gearbox setup and more.
This document provides installation and wiring instructions for the GrowerSelect 3-Phase 50 Hz Feed System Auger Power Drive Units. It emphasizes safety precautions, such as disconnecting power before servicing and wearing protective clothing. The guide details the gearbox setup, noting that the unit is preassembled with the output shaft at the top but can be rotated 180 degrees if required, provided the solid Hex Plug remains on the bottom and the Vent Plug is on top. Proper filling with specified 80-W90 Gear Oil is mandatory before operation.
| Voltage | 190 Volt or 380 Volt |
|---|---|
| Frequency | 50 Hz |
| Gear Oil Type | 80-W90 Gear Oil |
| Motor Power (HS9323D2-60) | 1.0 HP (,75 kW) |
| Motor Power (HS9321D6-50) | 1/2 HP (,37 kW) |
| Motor RPM | 352 or 364 |
The gearbox must be filled with the correct amount of specified 80-W90 Gear Oil prior to running the system.
Yes, the gearbox can be rotated 180 degrees so that the shaft is at the bottom if the specific application requires it.
Motor replacement and associated wiring changes should only be made by qualified and properly trained individuals.