This is a repair manual that introduces the use and maintenance of Super Runner Electric Series SR114E electric fryers.
This document is the Service & Parts Manual for the Frymaster Dean Super Runner Series SR114E electric fryer. It provides essential safety warnings, electrical power specifications, and detailed service procedures for authorized technicians. The manual covers the calibration of the temperature control knob and step-by-step instructions for replacing key components such as the temperature control board, transformer, contactor, relay, power switch, indicator lamp, temperature probe, high-limit thermostat, heating element, and frypot.
| Minimum Wire Size (14 kW, 208V, 3 Phase) | 6 AWG (4.11 mm) |
|---|---|
| Minimum Wire Size (14 kW, 240V, Single Phase) | 4 AWG (5.19 mm) |
| Minimum Wire Size (14 kW, 230/400V, 3 Phase) | 6 AWG (4.11 mm) |
| Torque for Probe Installation | 170-180 inch-pounds |
Copper wire suitable for at least 167°F (75°C) must be used for power connections.
No, this equipment is intended for indoor use only and must not be installed or operated in outdoor areas.
When the heating elements cycle on for the fourth time, the temperature should read within ±5°F (±3°C) of the setting.