This document is the user manual of the Fluke 1587/1577 insulation multimeter
This document serves as the user manual for the Fluke 1587, 1577, and 1587T insulation multimeters. It covers essential topics including safety information, accessory usage, and detailed instructions for making basic measurements such as AC and DC voltage, resistance, capacitance, and insulation testing. The guide also explains specific features like AutoHold mode, MIN/MAX/AVG recording, and battery management.
| Maximum Voltage Applied to any Terminal | 1000 V ac rms or dc |
|---|---|
| Operating Temperature | -20 °C to 55 °C |
| Battery Type | Four AA batteries |
| Weight | 550 g (1.2 lb.) |
| Insulation Measurement Range (Model 1587) | 0.01 M Ω to 2 G Ω |
| Insulation Test Voltages (Model 1587) | 50, 100, 250, 500, 1000 V |
| Insulation Measurement Range (Model 1577) | 0.1 M Ω to 600 M Ω |
| Insulation Test Voltages (Model 1577) | 500, 1000 V |
The warranty period is three years and begins on the date of shipment.
Fluke will provide an estimate of repair costs and obtain authorization before commencing the work.
The meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature.
The short-circuit test current is 1 mA nominal.