This document describes the service manual of 2510 and 2510 ECONOMINDER, including installation instructions, water pressure, electrical facilities, water quality test, etc.
This document provides service instructions for the Economy 2510 and 2510 ECONOMINDER water softeners. It details job specification requirements, including water pressure limits (minimum 20 psi, maximum 120 psi) and temperature constraints (maximum 110°F). The manual outlines installation procedures for plumbing and electrical connections, emphasizing the need for a firm base and proper drain line sizing.
| Minimum Water Pressure | 20 pounds |
|---|---|
| Maximum Water Pressure | 120 p.s.i. |
| Maximum Water Temperature | 110°F |
| Drain Line Size | 1/2" minimum |
| Backwash Flow Rate Limit | 7 gpm |
Turn the manual regeneration knob clockwise to engage the program wheel and start the regeneration program.
The backwash time is adjusted by adding or removing pins on the program wheel, where the number of pins times two equals the time in minutes.
Do not use granulated or rock salt; only use the appropriate salt for the brine tank.