The Nelsen AIO Filter System is an efficient and cost effective system for the removal of Iron and Sulphur. It maintains a compressed air pocket in the top of the tank while the system is in service. As the water passes thru the air pocket, Iron and Sulphur are oxidized. Additionally, dissolved oxygen is added to the water. The Nelsen AIO filter media bed then removes the Iron and Sulphur from the water.
This manual provides instructions for installing and operating the Nelsen AIO Filter System, designed to remove iron and sulfur from water through air oxidation and filtration. It includes media loading guidelines, system limitations, and regeneration cycles. The system maintains an air pocket in the tank during operation and requires daily backwashing to maintain performance.
Installation must follow specific plumbing guidelines, including placement after sediment or neutralizing filters and before water softeners. Media must be layered correctly, with specific instructions for Iron, Iron-Sulphur, and Katalox systems. Regeneration involves backwash, air recharge, rapid rinse, and brine refill steps, with cycle times adjustable based on water usage and iron levels.
| pH (Minimum) | 6.8 |
|---|---|
| Iron (Maximum) | 7 ppm |
| Sulphur (Maximum) | 4 ppm |
| Manganese (Maximum) | 5 ppm |
The maximum iron level is 7 ppm for Iron Filter Media, 2 ppm for Iron-Sulphur Media, and 10 ppm for Katalox Media.
The system can be set for daily regeneration or every two days. Do not set regeneration for longer than 3 days to avoid fouling the media.
Install the Nelsen AIO after sediment or neutralizing filters (e.g., calcite, corosex), unless outside faucets need to be free of iron.