This manual describes the installation and programming of the puronics terminator mp water conditioner.
This document is the Installation and Programming Manual for the Puronics Terminator MP water conditioner, which features SilverShield HYgene bacteriostatic protection. It details the setup procedures for the control valve, including entering Master Programming Mode to configure parameters such as unit capacity, feedwater hardness, and regeneration times. The manual also explains how to set the time of day, initiate manual regenerations, and manage the automatic Service Call Reminder feature.
| Flow Meter Type | ¾” Paddle Wheel Meter |
|---|---|
| Power Backup Duration | 48 hours |
| Unit Capacity (8” tank) | 20000 |
| Unit Capacity (10” tank) | 30000 |
| Unit Capacity (12” tank) | 40000 |
Press and hold the EXTRA CYCLE button for five seconds.
The control enters power-saving mode, stops monitoring water usage, but keeps time for up to 48 hours and stores remaining volume.
Press and hold either the UP or DOWN buttons until the programming icon replaces the service icon and the parameter display reads DO.